Discovery Hybrid Rheometer
Sensitivity, ease-of-use, and versatility to meet your needs and exceed your expectations.
Advances in core measurement technology enable more sensitive measurements with superior precision. This empowers you to measure lower viscosities and weaker liquid and soft-solid structure, while consuming less material. Superior dynamic performance gives a higher level of accuracy in measurements of G’ and G” so you can make decisions quickly, with confidence.
Thoughtful hardware and software design results in a complete system that simplifies every user interaction. Routine functions are faster and more intuitive, so you can accomplish more with less training.
The performance of the Discovery Hybrid Rheometer is supported by the widest range of powerful, easy-to-use environmental systems and accessories that allow you to replicate demanding environmental conditions, incorporate complementary simultaneous measurements, or extend your rheometer beyond conventional shear rheology.
The HR 10 builds on the field-proven accuracy and reliability of the Discovery Hybrid Rheometer family. Incorporating advanced technologies found on the HR 20 and HR 30 models, the HR 10 delivers industry-leading performance at a cost-effective price point that is suitable for a wide range of general viscosity and viscoelasticity measurements and for use in round-the-clock production control.
Performance
Sensitivity
Sensitivity
Measure the lowest stresses and smallest sample volumes with revolutionary torque sensitivity
Unrivaled low torque sensitivity empowers you to measure lower viscosities and weaker intermolecular structures while using lower sample volumes.
All Discovery Hybrid Rheometers feature TA’s patented Magnetic Thrust Bearing which reduces basic system friction by 70% compared to traditional designs. By eliminating the contributions of high pressure, turbulent air flow from the measurement system, lower torques can be measured reliably and accurately.
The unparalleled sensitivity of the magnetic thrust bearing is coupled with the NEW improved Advanced Drag Cup Motor. Enhanced torque precision increases the accuracy of every measurement, especially at low torques.
Dynamic Measurements
Dynamic Measurements
Report G’ and G” with confidence
The storage and loss modulus, G’ and G”, are two of the most insightful measurements provided by any rheometer. The HR 10’s Advanced Drag Cup Motor is optimized for accuracy in dynamic measurements. The low-mass and -radius design reduces system inertia by up to 80% compared to DC motors, minimizing corrections to oscillation data, especially at higher measurement frequencies. The result is a wider range of accurate measurement frequencies, material types, and experimental designs.
Strain and Stress Control
Strain and Stress Control
The measurement you want: Advanced Strain and Stress Control
The Discovery Hybrid Rheometer performs the experiment you want, whether stress-controlled, strain-controlled, or both. State-of-the-art high-speed electronics and the responsive Advanced Drag Cup Motor provide the fastest transient responses and accurate control in any type of deformation. Optional Direct Strain oscillation provides real-time strain control at every point of the oscillatory measurement.
Reliability
Reliability
The Discovery Hybrid Rheometers are designed with sensitivity to measure the softest materials, and are constructed to be rugged enough to handle the stiffest materials and toughest users.
A rigid cast aluminum frame and rugged linear ball slide provide more than 60% greater axial and torsional stiffness than other designs and permit gap position resolution of 0.02 µm.
Two high-stiffness radial bearings stabilize the system from side loads exerted by samples or operators while the Optical Encoder Dual Reader further cancels displacement measurement drift associated with testing very stiff samples over long times.
The Advanced Drag Cup Motor provides stable control and measurement even when operating under extreme conditions. Active and passive thermal systems manage heat and account for system temperature, guaranteeing measurement accuracy under all test conditions.
These innovations provide the most accurate and sensitive measurement, under even the most extreme experimental conditions.
Advanced Technology
Advanced Technology
True Position Sensor
The DHR includes the patented True Position Sensor (TPS) for true gap accuracy. The TPS is a high-resolution linear position sensor that measures and compensates for the effects of thermal expansion in real time. Unlike competitive devices, the TPS eliminates errors associated with thermal expansion without the need for special high inertia iron core geometries and environmental systems. The TPS works with all Smart Swap™ geometries and Smart Swap™ environmental systems.
(US Pat #10,161,843)
Normal Force Rebalance Transducer (FRT)
The Force Rebalance Transducer is the premier technology for normal force measurements. This active, non-compliant device accurately measures normal and axial forces without deflection. Competitive capacitive or strain gauge sensors rely on physical movement of the device to sense a force, resulting in measurement error. The FRT provides the most accurate normal force measurement by driving the linear motor to maintain zero deflection at all times and conditions.
Ease of Use
Sample handling
Sample handling
The NEW Discovery Hybrid Rheometer is your invisible partner in the lab, reducing the time from question to insight.
Load samples with confidence and ease
The Discovery Hybrid Rheometer is designed by rheometer users to make sample loading faster, easier, and improve measurement precision for every operator.
Expedite routine interactions with a gap positioning system that is 3× faster than other rheometers while maintaining a 0.02 µm gap resolution. A convenient tactile keypad places the most common actions where you need them most, including thoughtful features like automated trim gap, measurement position, and bearing lock.
Even more power is offered by the brand new One-Touch-Away™ app-style touchscreen that greatly enhances usability by placing key instrument features at your fingertips.
Every user will appreciate the brand new integrated 360° sample stage lighting that enhances visibility in any lab environment. The result is easier, more repeatable sample loading and trimming, leading to improved data accuracy and precision.
One-Touch-Away™
One-Touch-Away™
Revolutionary rheometer performance at your fingertips
The new Discovery Hybrid Rheometer boasts a brand-new One-Touch-Away™ app-style touchscreen that greatly enhances usability by placing key instrument features at your fingertips.
- Ergonomic design for easy viewing and operation
- Packed with functionality to simplify operation and enhance user experience
The app-style touch screen includes:
- Start/stop experiments
- Set temperature
- Set gap
- Controlled rotation for sample loading
- Procedure and sample details
- Real-time signals
- Test and instrument status at a glance
- User prompts
The app-style touchscreen, powerful new TRIOS software, and quick robust calibration routines work seamlessly to dramatically improve laboratory workflows and productivity.
Guided Methods
Polymer Guided Methods
Guided Methods for Solid Polymer Torsional Analysis and Polymer Melts provide an easy-to-use interface for new users to obtain desired results with minimal training.
- Improves productivity by significantly reducing training time for new users
- Easy-to-follow interactive and visual guidelines for experimental setup and method development
- Preconfigured experiment templates that can be customized to meet your specific testing needs
- Improved intra-lab and inter-lab precision of critical analytical measurements
- Automate post-test analysis and reporting of product relevant KPIs such as Tg, modulus, crossover frequency (wc) and modulus (Gc).
- Click on the software section or go to Guided Methods for more details
Versatility
Versatility is being ready to face whatever the day brings. Whatever that may be, the NEW Discovery Hybrid Rheometer will be ready. The Discovery Hybrid Rheometer features the widest range of powerful, easy-to-use environmental systems and accessories that allow you to replicate demanding environmental conditions, incorporate complementary simultaneous measurements, or extend your rheometer beyond conventional shear rheology.
Smart Swap™ Geometries
Smart Swap™ Geometries
The NEW Smart Swap™ 2 geometry system features an all new system for optical information storage and transfer. This system provides greater storage and durability than chip-based systems. When attached, the complete geometry information, including unique dimensions is automatically detected and the software is appropriately configured.
Smart Swap™ Temperature Systems and Accessories
Smart Swap™ Temperature Systems and Accessories
Only TA Instruments offers the convenience and versatility of Smart Swap™ temperature control options and accessories. Smart Swap™ options are attached to the instrument on its unique magnetic base, providing faster, easier installation than mechanical systems. Once attached, the instrument automatically detects and configures the system for operation.
Software
TRIOS Software
TA Instruments’ state-of-the-art software package uses cutting-edge technology for instrument control, data collection, and data analysis for thermal analysis and rheology. The intuitive user interface allows you to simply and effectively program experiments, and move easily between processing experiments and viewing and analyzing data
- Control multiple instruments with a single PC and software package
- Overlay and compare results across techniques including DSC,TGA, DMA, SDT, TMA and rheometers
- One-click repeated analysis for increased productivity
- Automated custom report generation including: experimental details, data plots and tables, analysis results
- Convenient data export to plain-text, CSV, XML, Excel®, Word®, PowerPoint®, and image formats
- Optional TRIOS Guardian with electronic signatures for audit trail and data integrity including U.S. FDA 21 CFR 11 compliance
JSON Export
JSON Export: The Future of Data Management
- Seamless Integration: Convert your TRIOS data into the open standard JSON format, making it easy to integrate with programming tools, data science workflows, and lab systems (e.g. LIMS). JSON is available:
- Automatically on every save (enabled in options)
- Through manual export dialogs
- As part of the “Send to LIMS” functionality
- Via the “Batch” processing dialog or from the command line
- In TRIOS AutoPilot
- Data Consistency: Our publicly available JSON schema ensures a consistent data structure, allowing you to write code once and apply it universally across all your data files.
- Python Library: Use our open-sourced python library, TA Data Kit, to simplify your data ingestion or learn how to take advantage of the power of our data with our code examples.
For more information, click here
User Experience
User Experience
TRIOS Software provides the right experience for every user
TRIOS for the Discovery Hybrid Rheometer features two powerful user interfaces that present users with what they need to collect the data they want.
TRIOS Express helps users to design the most common measurements quickly and easily. Simple forms and sensible defaults streamline the process of experiment design and execution.
TRIOS Unlimited gives you complete control. A robust set of detailed experimental controls and data collection options ensures that you will be able to design the experiment you envision and collect the data you need.
Complete Data Record
Complete Data Record
The advanced data collection system automatically saves all relevant signals, active calibrations, and system settings. Waveforms for each data point may be displayed as Lissajous plots and provide a visual representation of the stress-strain relationship. This comprehensive set of information is invaluable for method development, procedure deployment and data validation.
Data Analysis
Data Analysis
Complete Data Analysis Capabilities
A comprehensive set of relevant tools are available for real-time data analysis, even during experiments. Gain actionable insights into your material behavior through a powerful and versatile set of features seamlessly integrated into TRIOS.
All Standard Analyses
- Onset and endset analysis
- Signal maximum and minimum
- Signal change
- Modulus crossover
- Curve values at specific X or Y points
- 1st and 2nd derivatives
- Area under the curve
- Peak height
- Peak integration and running integral
- Mathematical fitting: straight line, polynomial, or exponential
- Statistical functions
Advanced Analysis Capabilities
- More than 10 flow models including automatic model selection based on best fit to experimental data
- Time-Temperature Superposition (TTS) analysis with automatic curve shifting and Mastercurve generation
- Activation Energy calculation
- WLF coefficient calculation
- Convert between temperature ramps and frequency sweeps
- Cole-Cole, Van Gurp-Palmen, and Lissajous plots
- Built-in models for: discrete and continuous relaxation or retardation spectra, Oldroyd and Spriggs models
- Creep ringing analysis by Kelvin, Maxwell, or Jeffreys models
- Viscoelastic transformations to interconvert between oscillation, stress relaxation, stress growth, creep, relaxation spectra, retardation spectra, and memory functions.
- Advanced custom analysis with user-defined variables and models
- Cox-Merz: η*(ω)→η()
- Fluid Inertia Correction
- Rabinowicz Correction
- Direct Creep – Oscillation conversion
- Discrete Fourier Transformation (DFT)
- Window Correlation
AutoPilot
AutoPilot
Experience a new paradigm in software functionality and unleash the full potential of your Discovery Hybrid Rheometer with AutoPilot, a premium feature that enables complete automation of powerful TRIOS software.
AutoPilot allows users to quickly and easily create automated routines: from test methods to data analysis and report generation. These routines empower laboratories to streamline and standardize operations and decision-making across local or global laboratory enterprises. From quality control to research and development, laboratory environments of all types will benefit from increased productivity, improved data precision, and reduced training time
See AutoPilot for Discovery HR
Guided Methods
Polymer Guided Methods
Guided Methods for Solid Polymer Torsional Analysis and Polymer Melts provide an easy-to-use interface for new users to obtain desired results with minimal training.
Torsion analyses of solids
-
- Step-by-step instructions for sample loading
- Pre-configured experiment templates with customizable parameters
- Automated post-test analyses to report the product relevant KPIs such as Tg and modulus.
Polymer melts
-
- Step-by-step instructions for sample loading and trimming
- Pre-configured experiment templates with customizable parameters
- Automated post-test analyses to report the product relevant KPIs such as crossover frequency (wc) and modulus (Gc) which can be correlated with MW and MWD
World’s Most Versatile Platform for Rheological Measurements
All DHR temperature systems and accessories are designed with superior performance and ease-of-use in mind. Only TA Instruments’ DHR offers the convenience and versatility of Smart Swap™ geometries, temperature systems, and accessories. Smart Swap™ technologies provide fast and easy interchanging of accessories and automatic detection and configuration of the rheometer for operation.
Glovebox Installaton
Often high-performance materials react instantaneously with oxygen or humidity in ambient air, altering their properties and/or leading to safety risks due to uncontrolled exothermal reactions. Some examples for materials requiring inert protective atmosphere handling are Li-ion battery components, pharmaceuticals, chemicals used in semiconductor production and catalysts. An adapter kit enables seamless installation of Discovery HR series instruments in the inert environment of a glovebox.
It has never been so simple to analyze atmosphere-sensitive materials in inert protective environments. Robust design and state-of-the-art technology ensure the hybrid rheometer performance is not impacted, delivering the same accuracy and precision as when operated outside a glovebox.
Discovery HR instruments can be operated in N2 or Ar purged gloveboxes covering all industries’ needs.
Specifications
Specification | HR 10 |
Bearing Type, Thrust | Magnetic |
Bearing Type, Radial | Porous Carbon |
Motor Design | Drag Cup |
Minimum Torque (nN.m) Oscillation | 5 |
Minimum Torque (nN.m) Steady Shear | 5 |
Maximum Torque (mN.m) | 200 |
Torque Resolution (nN.m) | 0.1 |
Minimum Frequency (Hz) | 1.0E-07 |
Maximum Frequency (Hz) | 100 |
Minimum Angular Velocity [1] (rad/s) | 0 |
Maximum Angular Velocity (rad/s) | 300 |
Displacement Transducer | Optical encoder |
Optical Encoder Dual Reader | N/A |
Displacement Resolution (nrad) | 10 |
Step Time, Strain [2] (ms) | 15 |
Step Time, Rate [2] (ms) | 5 |
Normal/Axial Force Transducer | FRT |
Maximum Normal Force (N) | 50 |
Normal Force Sensitivity (N) | 0.01 |
Normal Force Resolution (mN) | 1 |
[1]Zero in controlled stress mode. Controlled rate mode depends on duration of point being measured and sampling time.
[2] Results at 99% of commanded value
Instrument Features
True Position Sensor (TPS) | |
Controlled stress (steady, transient, oscillation) | |
Controlled strain (steady, transient, iterative oscillation) | |
Normal Force measurements with FRT | |
One Touch Away Display | |
Integrated Sample Lighting | |
FastTrack | |
Direct Strain (oscillation) (optional) | |
Axial and tack testing (optional) | |
AutoPilot (optional) |
- Description
-
Advances in core measurement technology enable more sensitive measurements with superior precision. This empowers you to measure lower viscosities and weaker liquid and soft-solid structure, while consuming less material. Superior dynamic performance gives a higher level of accuracy in measurements of G’ and G” so you can make decisions quickly, with confidence.
Thoughtful hardware and software design results in a complete system that simplifies every user interaction. Routine functions are faster and more intuitive, so you can accomplish more with less training.
The performance of the Discovery Hybrid Rheometer is supported by the widest range of powerful, easy-to-use environmental systems and accessories that allow you to replicate demanding environmental conditions, incorporate complementary simultaneous measurements, or extend your rheometer beyond conventional shear rheology.
The HR 10 builds on the field-proven accuracy and reliability of the Discovery Hybrid Rheometer family. Incorporating advanced technologies found on the HR 20 and HR 30 models, the HR 10 delivers industry-leading performance at a cost-effective price point that is suitable for a wide range of general viscosity and viscoelasticity measurements and for use in round-the-clock production control.
- Performance
-
Performance
Sensitivity
Sensitivity
Measure the lowest stresses and smallest sample volumes with revolutionary torque sensitivity
Unrivaled low torque sensitivity empowers you to measure lower viscosities and weaker intermolecular structures while using lower sample volumes.All Discovery Hybrid Rheometers feature TA’s patented Magnetic Thrust Bearing which reduces basic system friction by 70% compared to traditional designs. By eliminating the contributions of high pressure, turbulent air flow from the measurement system, lower torques can be measured reliably and accurately.
The unparalleled sensitivity of the magnetic thrust bearing is coupled with the NEW improved Advanced Drag Cup Motor. Enhanced torque precision increases the accuracy of every measurement, especially at low torques.
Dynamic Measurements
Dynamic Measurements
Report G’ and G” with confidence
The storage and loss modulus, G’ and G”, are two of the most insightful measurements provided by any rheometer. The HR 10’s Advanced Drag Cup Motor is optimized for accuracy in dynamic measurements. The low-mass and -radius design reduces system inertia by up to 80% compared to DC motors, minimizing corrections to oscillation data, especially at higher measurement frequencies. The result is a wider range of accurate measurement frequencies, material types, and experimental designs.
Strain and Stress Control
Strain and Stress Control
The measurement you want: Advanced Strain and Stress Control
The Discovery Hybrid Rheometer performs the experiment you want, whether stress-controlled, strain-controlled, or both. State-of-the-art high-speed electronics and the responsive Advanced Drag Cup Motor provide the fastest transient responses and accurate control in any type of deformation. Optional Direct Strain oscillation provides real-time strain control at every point of the oscillatory measurement.
Reliability
Reliability
The Discovery Hybrid Rheometers are designed with sensitivity to measure the softest materials, and are constructed to be rugged enough to handle the stiffest materials and toughest users.
A rigid cast aluminum frame and rugged linear ball slide provide more than 60% greater axial and torsional stiffness than other designs and permit gap position resolution of 0.02 µm.
Two high-stiffness radial bearings stabilize the system from side loads exerted by samples or operators while the Optical Encoder Dual Reader further cancels displacement measurement drift associated with testing very stiff samples over long times.
The Advanced Drag Cup Motor provides stable control and measurement even when operating under extreme conditions. Active and passive thermal systems manage heat and account for system temperature, guaranteeing measurement accuracy under all test conditions.
These innovations provide the most accurate and sensitive measurement, under even the most extreme experimental conditions.
Advanced Technology
Advanced Technology
True Position Sensor
The DHR includes the patented True Position Sensor (TPS) for true gap accuracy. The TPS is a high-resolution linear position sensor that measures and compensates for the effects of thermal expansion in real time. Unlike competitive devices, the TPS eliminates errors associated with thermal expansion without the need for special high inertia iron core geometries and environmental systems. The TPS works with all Smart Swap™ geometries and Smart Swap™ environmental systems.
(US Pat #10,161,843)
Normal Force Rebalance Transducer (FRT)
The Force Rebalance Transducer is the premier technology for normal force measurements. This active, non-compliant device accurately measures normal and axial forces without deflection. Competitive capacitive or strain gauge sensors rely on physical movement of the device to sense a force, resulting in measurement error. The FRT provides the most accurate normal force measurement by driving the linear motor to maintain zero deflection at all times and conditions. - Ease of Use
-
Ease of Use
Sample handling
Sample handling
The NEW Discovery Hybrid Rheometer is your invisible partner in the lab, reducing the time from question to insight.
Load samples with confidence and ease
The Discovery Hybrid Rheometer is designed by rheometer users to make sample loading faster, easier, and improve measurement precision for every operator.
Expedite routine interactions with a gap positioning system that is 3× faster than other rheometers while maintaining a 0.02 µm gap resolution. A convenient tactile keypad places the most common actions where you need them most, including thoughtful features like automated trim gap, measurement position, and bearing lock.
Even more power is offered by the brand new One-Touch-Away™ app-style touchscreen that greatly enhances usability by placing key instrument features at your fingertips.
Every user will appreciate the brand new integrated 360° sample stage lighting that enhances visibility in any lab environment. The result is easier, more repeatable sample loading and trimming, leading to improved data accuracy and precision.
One-Touch-Away™
One-Touch-Away™
Revolutionary rheometer performance at your fingertips
The new Discovery Hybrid Rheometer boasts a brand-new One-Touch-Away™ app-style touchscreen that greatly enhances usability by placing key instrument features at your fingertips.
- Ergonomic design for easy viewing and operation
- Packed with functionality to simplify operation and enhance user experience
The app-style touch screen includes:
- Start/stop experiments
- Set temperature
- Set gap
- Controlled rotation for sample loading
- Procedure and sample details
- Real-time signals
- Test and instrument status at a glance
- User prompts
The app-style touchscreen, powerful new TRIOS software, and quick robust calibration routines work seamlessly to dramatically improve laboratory workflows and productivity.
Guided Methods
Polymer Guided Methods
Guided Methods for Solid Polymer Torsional Analysis and Polymer Melts provide an easy-to-use interface for new users to obtain desired results with minimal training.
- Improves productivity by significantly reducing training time for new users
- Easy-to-follow interactive and visual guidelines for experimental setup and method development
- Preconfigured experiment templates that can be customized to meet your specific testing needs
- Improved intra-lab and inter-lab precision of critical analytical measurements
- Automate post-test analysis and reporting of product relevant KPIs such as Tg, modulus, crossover frequency (wc) and modulus (Gc).
- Click on the software section or go to Guided Methods for more details
- Versatility
-
Versatility
Versatility is being ready to face whatever the day brings. Whatever that may be, the NEW Discovery Hybrid Rheometer will be ready. The Discovery Hybrid Rheometer features the widest range of powerful, easy-to-use environmental systems and accessories that allow you to replicate demanding environmental conditions, incorporate complementary simultaneous measurements, or extend your rheometer beyond conventional shear rheology.
Smart Swap™ Geometries
Smart Swap™ Geometries
The NEW Smart Swap™ 2 geometry system features an all new system for optical information storage and transfer. This system provides greater storage and durability than chip-based systems. When attached, the complete geometry information, including unique dimensions is automatically detected and the software is appropriately configured.
Smart Swap™ Temperature Systems and Accessories
Smart Swap™ Temperature Systems and Accessories
Only TA Instruments offers the convenience and versatility of Smart Swap™ temperature control options and accessories. Smart Swap™ options are attached to the instrument on its unique magnetic base, providing faster, easier installation than mechanical systems. Once attached, the instrument automatically detects and configures the system for operation.
- Software
-
Software
TRIOS Software
TA Instruments’ state-of-the-art software package uses cutting-edge technology for instrument control, data collection, and data analysis for thermal analysis and rheology. The intuitive user interface allows you to simply and effectively program experiments, and move easily between processing experiments and viewing and analyzing data
- Control multiple instruments with a single PC and software package
- Overlay and compare results across techniques including DSC,TGA, DMA, SDT, TMA and rheometers
- One-click repeated analysis for increased productivity
- Automated custom report generation including: experimental details, data plots and tables, analysis results
- Convenient data export to plain-text, CSV, XML, Excel®, Word®, PowerPoint®, and image formats
- Optional TRIOS Guardian with electronic signatures for audit trail and data integrity including U.S. FDA 21 CFR 11 compliance
JSON Export
JSON Export: The Future of Data Management
- Seamless Integration: Convert your TRIOS data into the open standard JSON format, making it easy to integrate with programming tools, data science workflows, and lab systems (e.g. LIMS). JSON is available:
- Automatically on every save (enabled in options)
- Through manual export dialogs
- As part of the “Send to LIMS” functionality
- Via the “Batch” processing dialog or from the command line
- In TRIOS AutoPilot
- Data Consistency: Our publicly available JSON schema ensures a consistent data structure, allowing you to write code once and apply it universally across all your data files.
- Python Library: Use our open-sourced python library, TA Data Kit, to simplify your data ingestion or learn how to take advantage of the power of our data with our code examples.
For more information, click here
User Experience
User Experience
TRIOS Software provides the right experience for every user
TRIOS for the Discovery Hybrid Rheometer features two powerful user interfaces that present users with what they need to collect the data they want.
TRIOS Express helps users to design the most common measurements quickly and easily. Simple forms and sensible defaults streamline the process of experiment design and execution.
TRIOS Unlimited gives you complete control. A robust set of detailed experimental controls and data collection options ensures that you will be able to design the experiment you envision and collect the data you need.
Complete Data Record
Complete Data Record
The advanced data collection system automatically saves all relevant signals, active calibrations, and system settings. Waveforms for each data point may be displayed as Lissajous plots and provide a visual representation of the stress-strain relationship. This comprehensive set of information is invaluable for method development, procedure deployment and data validation.
Data Analysis
Data Analysis
Complete Data Analysis Capabilities
A comprehensive set of relevant tools are available for real-time data analysis, even during experiments. Gain actionable insights into your material behavior through a powerful and versatile set of features seamlessly integrated into TRIOS.All Standard Analyses
- Onset and endset analysis
- Signal maximum and minimum
- Signal change
- Modulus crossover
- Curve values at specific X or Y points
- 1st and 2nd derivatives
- Area under the curve
- Peak height
- Peak integration and running integral
- Mathematical fitting: straight line, polynomial, or exponential
- Statistical functions
Advanced Analysis Capabilities
- More than 10 flow models including automatic model selection based on best fit to experimental data
- Time-Temperature Superposition (TTS) analysis with automatic curve shifting and Mastercurve generation
- Activation Energy calculation
- WLF coefficient calculation
- Convert between temperature ramps and frequency sweeps
- Cole-Cole, Van Gurp-Palmen, and Lissajous plots
- Built-in models for: discrete and continuous relaxation or retardation spectra, Oldroyd and Spriggs models
- Creep ringing analysis by Kelvin, Maxwell, or Jeffreys models
- Viscoelastic transformations to interconvert between oscillation, stress relaxation, stress growth, creep, relaxation spectra, retardation spectra, and memory functions.
- Advanced custom analysis with user-defined variables and models
- Cox-Merz: η*(ω)→η()
- Fluid Inertia Correction
- Rabinowicz Correction
- Direct Creep – Oscillation conversion
- Discrete Fourier Transformation (DFT)
- Window Correlation
AutoPilot
AutoPilot
Experience a new paradigm in software functionality and unleash the full potential of your Discovery Hybrid Rheometer with AutoPilot, a premium feature that enables complete automation of powerful TRIOS software.
AutoPilot allows users to quickly and easily create automated routines: from test methods to data analysis and report generation. These routines empower laboratories to streamline and standardize operations and decision-making across local or global laboratory enterprises. From quality control to research and development, laboratory environments of all types will benefit from increased productivity, improved data precision, and reduced training time
See AutoPilot for Discovery HR
Guided Methods
Polymer Guided Methods
Guided Methods for Solid Polymer Torsional Analysis and Polymer Melts provide an easy-to-use interface for new users to obtain desired results with minimal training.
Torsion analyses of solids
-
- Step-by-step instructions for sample loading
- Pre-configured experiment templates with customizable parameters
- Automated post-test analyses to report the product relevant KPIs such as Tg and modulus.
Polymer melts
-
- Step-by-step instructions for sample loading and trimming
- Pre-configured experiment templates with customizable parameters
- Automated post-test analyses to report the product relevant KPIs such as crossover frequency (wc) and modulus (Gc) which can be correlated with MW and MWD
- Accessories
-
World’s Most Versatile Platform for Rheological Measurements
All DHR temperature systems and accessories are designed with superior performance and ease-of-use in mind. Only TA Instruments’ DHR offers the convenience and versatility of Smart Swap™ geometries, temperature systems, and accessories. Smart Swap™ technologies provide fast and easy interchanging of accessories and automatic detection and configuration of the rheometer for operation.
Glovebox Installaton
Often high-performance materials react instantaneously with oxygen or humidity in ambient air, altering their properties and/or leading to safety risks due to uncontrolled exothermal reactions. Some examples for materials requiring inert protective atmosphere handling are Li-ion battery components, pharmaceuticals, chemicals used in semiconductor production and catalysts. An adapter kit enables seamless installation of Discovery HR series instruments in the inert environment of a glovebox.
It has never been so simple to analyze atmosphere-sensitive materials in inert protective environments. Robust design and state-of-the-art technology ensure the hybrid rheometer performance is not impacted, delivering the same accuracy and precision as when operated outside a glovebox.
Discovery HR instruments can be operated in N2 or Ar purged gloveboxes covering all industries’ needs.
- Specs.
-
Specifications
Specification HR 10 Bearing Type, Thrust Magnetic Bearing Type, Radial Porous Carbon Motor Design Drag Cup Minimum Torque (nN.m) Oscillation 5 Minimum Torque (nN.m) Steady Shear 5 Maximum Torque (mN.m) 200 Torque Resolution (nN.m) 0.1 Minimum Frequency (Hz) 1.0E-07 Maximum Frequency (Hz) 100 Minimum Angular Velocity [1] (rad/s) 0 Maximum Angular Velocity (rad/s) 300 Displacement Transducer Optical encoder Optical Encoder Dual Reader N/A Displacement Resolution (nrad) 10 Step Time, Strain [2] (ms) 15 Step Time, Rate [2] (ms) 5 Normal/Axial Force Transducer FRT Maximum Normal Force (N) 50 Normal Force Sensitivity (N) 0.01 Normal Force Resolution (mN) 1 [1]Zero in controlled stress mode. Controlled rate mode depends on duration of point being measured and sampling time.
[2] Results at 99% of commanded value
Instrument Features
True Position Sensor (TPS) Controlled stress (steady, transient, oscillation) Controlled strain (steady, transient, iterative oscillation) Normal Force measurements with FRT One Touch Away Display Integrated Sample Lighting FastTrack Direct Strain (oscillation) (optional) Axial and tack testing (optional) AutoPilot (optional) - Video
-