Blog-Antibody Comparison Image

Why DSC Testing is a Critical Step in Developing Biosimilar Drugs

Biologic therapies derived from living organisms have revolutionized the treatment of complex diseases, yet their high development costs are often passed onto patients. Biosimilar drugs offer a promising solution to reduce costs while maintaining therapeutic efficacy. Unlike generic drugs, biosimilars cannot be exact replicas of their reference biologics due to their complex structures, necessitating rigorous testing and regulatory approval.

Syringe and needle with glass medical ampoule vials for injection. Medicine is dry white drug penicillin powder or liquid with of aqueous solution in ampulla

Unlocking Stability: The Crucial Role of Thermal Analysis in Lyophilization Temperature Optimization

The method of drug delivery significantly influences the final stages of the manufacturing process. Currently, lyophilization—a widely adopted technique—enables drug developers to stabilize formulations and therapeutic molecules using a validated commercial approach. In this process, precise control of pressure and temperature within a lyophilizer facilitates the removal of liquids from formulations containing thermally sensitive or hydrolytically unstable active pharmaceutical ingredients or formulation components.

Candidate selection

후보물질 선정 후 제형 최적화

의약품 개발은 발견부터 시작하여, 성공할 경우 정부의 시판 승인으로 끝나는 길고 복잡한 과정입니다. 아래에 설명된 의약품 개발 프로세스의 각 단계에는 승인된 약물 성분에 대한 적절한 선도물질 및 후보물질을 하향 선택한다는 구체적인 목표가 있습니다.

Antibody binding to human cell receptors

How to Assess Binding in Drug Discovery

The most popular tool used to characterize binding in the late-discovery phase of drug development is isothermal titration calorimetry (ITC). ITC is a high-resolution method for complete characterization of the basic chemical details of a binding interaction. The calorimeters accomplish this by measuring the heat that is released or absorbed when molecules interact with each other.

미세 열량 측정법의 역사

18세기 많은 과학자들이 열의 본질에 의문을 제기했다. 아이작 뉴턴(Isaac Newton)은 열이 입자의 진동에 의해 전달된다고 생각했고, 로버트 훅(Robert Hooke)은 열이 각 신체 부분의 운동에 의해 발생하는 신체의 특성이라고 생각했다. 그러나 열 측정 역사에 기여한 최초의 유명한 과학자는 스코틀랜드의 의사이며 화학자인 조셉 블랙(Joseph Black)이다. 1761년 블랙은 정밀 측정법을 사용해 녹는점의 얼음이나 끓는점의 물에 열을 가해도 온도가 변하지 않는다는 사실을 발견했다.1 이 발견을 통해 블랙은 온도와 열을 구별한 최초의 과학자가 되었으며, 이는 열역학의 시작을 알렸다.

ITC(등온 적정 열량계)란 무엇일까요?

Isothermal Titration Calorimetry (ITC) is an experimental method used to measure the amount of heat released or consumed during a bimolecular chemical reaction. Chemical reactions can be either exothermic or endothermic, depending on the relative energetic stabilities of the reactants. Isothermal titration calorimetry can be used to quantify the magnitude of the heat change during the reaction.

고분자의 생물 물리학적 특성화를 위한 미세열량측정

생물학적 고분자는 모든 세포의 기본 구성 요소로서 모든 생명체에 필수적입니다. 이러한 필수 분자는 탄수화물, 지질, 단백질, 핵산의 4가지 주요 부문으로 분류됩니다. 생물학적 고분자를 특성화하는 것은 고분자의 기능과 관계를 이해함에 있어 매우 중요하며, 이는 새로운 치료법과 치료법의 개발로 이어질 수 있습니다. 고분자 연구의 이 분야에서 생물치료제 약물 요법은 질병 및/또는 세포의 사멸 가능성이 있는 고분자 상호작용에 초점을 맞추고 있습니다.