Guided Methods 

Polymer Workflow Automation

Contact Us

 

TA Instruments’ industry-leading software streamlined for polymer use. Guided Methods for polymer applications is available on the Differential Scanning Calorimeter, Thermogravimetric Analyzer, and Discovery Hybrid Rheometer and offers pre-made workflow solutions. From setting up instruments, geometries, and samples to automating analysis and reporting, new users can effectively use instrumentation with minimal training.

Guided Methods provides walk up and use functionality by codifying polymer workflows. Through leveraging OneTouch view and the power of AutoPilot, new users need significantly less training to set up test methods, run tests, and execute analysis.

  • Improves productivity by significantly reducing training time for new users
  • Easy-to-follow interactive and visual guidelines for experimental setup and method development
  • Preconfigured experiment templates that can be customized to meet your specific testing needs
  • Improved intra-lab and inter-lab precision of critical analytical measurements
  • Automate post-test analysis and reporting of product relevant KPIs

Guided Methods for Initial Crystallinity, Glass Transitions, Percent Cure, and Thermal Transitions provide an easy-to-use interface for new users to obtain desired results with minimal training.

Initial Crystallinity

  • Preconfigured ramp templates with customizable ramp rates and start/end temperatures
  • Automatically calculates and reports the crystallinity using the 100% crystalline value

Glass Transitions

  • Preconfigured ramp templates with customizable ramp rates and start/end temperatures
  • Automatically intelligently analyzes and reports all thermal transitions and prompts the user with the glass transition value(s)

Percent Cure

  • Preconfigured ramp templates with customizable ramp rates and start/end temperatures
  • Automatically calculates and reports the percent cure using the 100% cure enthalpy value

Thermal Transitions

  • Consists of two separate methods, one for a single heat and another for a heat-cool-heat cycle
  • Preconfigured ramp templates with customizable ramp rates and start/end temperatures
  • Automatically intelligently analyzes and reports all thermal transitions in both heat steps

A Guided Method for Decomposition and Residue provides an easy-to-use interface for new users to obtain desired results with minimal training.

Decomposition and Residue

  • Preconfigured ramp templates with customizable ramp rates and start/end temperatures
  • Automatically intelligently analyzes and reports all weight loss events and the final residue

Guided Methods for Solid Polymer Torsional Analysis and Polymer Melts provide an easy-to-use interface for new users to obtain desired results with minimal training.

Solid Polymer Torsional Analysis

  • Step-by-step instructions for sample loading
  • Preconfigured experiment templates with customizable parameters
  • Automate post-test analyses to report the product-relevant KPIs such as Tg and modulus.

Polymer Melt Analysis

  • Step-by-step instructions for sample loading and trimming
  • Preconfigured experiment templates with customizable parameters
  • Automate post-test analyses to report the product-relevant KPIs such as crossover frequency (wc) and modulus (Gc) which can be correlated with MW and MWD
Ease-of-Use

Guided Methods provides walk up and use functionality by codifying polymer workflows. Through leveraging OneTouch view and the power of AutoPilot, new users need significantly less training to set up test methods, run tests, and execute analysis.

  • Improves productivity by significantly reducing training time for new users
  • Easy-to-follow interactive and visual guidelines for experimental setup and method development
  • Preconfigured experiment templates that can be customized to meet your specific testing needs
  • Improved intra-lab and inter-lab precision of critical analytical measurements
  • Automate post-test analysis and reporting of product relevant KPIs
Differential Scanning Calorimetry

Guided Methods for Initial Crystallinity, Glass Transitions, Percent Cure, and Thermal Transitions provide an easy-to-use interface for new users to obtain desired results with minimal training.

Initial Crystallinity

  • Preconfigured ramp templates with customizable ramp rates and start/end temperatures
  • Automatically calculates and reports the crystallinity using the 100% crystalline value

Glass Transitions

  • Preconfigured ramp templates with customizable ramp rates and start/end temperatures
  • Automatically intelligently analyzes and reports all thermal transitions and prompts the user with the glass transition value(s)

Percent Cure

  • Preconfigured ramp templates with customizable ramp rates and start/end temperatures
  • Automatically calculates and reports the percent cure using the 100% cure enthalpy value

Thermal Transitions

  • Consists of two separate methods, one for a single heat and another for a heat-cool-heat cycle
  • Preconfigured ramp templates with customizable ramp rates and start/end temperatures
  • Automatically intelligently analyzes and reports all thermal transitions in both heat steps
Thermogravimetric Analysis

A Guided Method for Decomposition and Residue provides an easy-to-use interface for new users to obtain desired results with minimal training.

Decomposition and Residue

  • Preconfigured ramp templates with customizable ramp rates and start/end temperatures
  • Automatically intelligently analyzes and reports all weight loss events and the final residue
Rheometry

Guided Methods for Solid Polymer Torsional Analysis and Polymer Melts provide an easy-to-use interface for new users to obtain desired results with minimal training.

Solid Polymer Torsional Analysis

  • Step-by-step instructions for sample loading
  • Preconfigured experiment templates with customizable parameters
  • Automate post-test analyses to report the product-relevant KPIs such as Tg and modulus.

Polymer Melt Analysis

  • Step-by-step instructions for sample loading and trimming
  • Preconfigured experiment templates with customizable parameters
  • Automate post-test analyses to report the product-relevant KPIs such as crossover frequency (wc) and modulus (Gc) which can be correlated with MW and MWD