View allAdhesives & SealantsApplication NotesApplicationsArchiveARES G2 AccessoriesARES RheometerAutomated Density TesterAutomated Hardness TesterBatteriesBatteries & Battery MaterialsBatteriesBatteriesBiopharmaBiopharmaceuticalsBlog ApplicationsBlog Techniquescardiovascular instrumentsCase StudiesCeramicsCompositesCompositesDHR AccessoriesDifferential Scanning CalorimetersDifferential Scanning CalorimetryDIL 830 SeriesDilatometersDilatometry videosDilatometryDilatometryDiscovery Hybrid RheometersDraftsDynamic Mechanical Analysis (DMA)Dynamic Mechanical AnalyzersDynamic Mechanical Analyzers (DMA)Dynamic Mechanical Analyzers (Rheology)Dynamic Mechanical Analyzers (Thermal Analysis)ElastomersElectroForceElectroForceElectroForce NotesElectroForceElectroForceElectroForceElectronic Materials & ProductsElectronicsEnd of Life ProductsEngineered MaterialsFine & Specialty ChemicalsFlash Diffusivity SystemsFlash DiffusivityFlash Diffusivity VideosFood ProductsGeneralGlass ProductsGuarded heat flow meterHeating MicroscopesHigh Pressure AnalyzersHigh Throughput DSCHorizontal DilatometersIn-Person TrainingInorganics - OtherInorganics - MineralsInsulation & Building MaterialsIsothermal CalorimetryIsothermal Titration CalorimetryLaser FlashLoad frame systemsMaterial CharacterizationMechanical TestingMechanical TestingMedical Device TestingMedical DevicesMetals ProductsMicrocalorimetry videosMicrocalorimetryMicrocalorimetryMicrocalorimetryMicrocalorimetry NotesMicrocalorimetryMooney ViscometerMoving Die RheometerMulti-Specimen FatigueNews & InfoOils, Lubricants, & FluidsOptical DilatometersOptical FleximeterOrganic Chemicals & ProductsPaints, Inks, & CoatingsPercarbonatesPersonal Care & Household ProductsPetroleum ProductsPharmaceuticalsPharmaceuticalsPolymersPolymersprivateProduct videosProductsPromotionsQ SeriesQuenching DilatometersQuick start guidesRheology videosRheologyRheologyRheology AccessoryRheologyRheology NotesRheologyRotational ViscometerRubberRubber AccessoriesRubberRubber Process AnalyzersRubberRubber TestingRubber TestingRubber TestingRubothermSeminarsService VideosSimultaneous Thermal AnalyzerSoftwareSoftwareTA Quick Talk VideosTech TipsTestbench and Planar Biaxial systemsThermal Analysis videosThermal AnalysisThermal AnalysisThermal Analysis NotesThermal AnalysisThermal ApplicationsThermal Conductivity & DiffusivityThermal Conductivity MeterThermal ConductivityThermal Conductivity VideosThermogravimetric AnalysisThermomechanical AnalyzersThermophysical NotesThermophysical Properties NotesTrainingUncategorizedVapor Sorption AnalysisVertical DilatometersVideosDilatometryWebinarsMicrocalorimetryRheologyRubberThermal AnalysisXenon Flash

DIL 803 Dual Sample Dilatometer

To maximize sample throughput, DIL 803 and DIL 803L offers two-samples simultaneous operation. DIL803 and DIL 803L can also be operated with an inert reference sample for quasi-differential measurement, reducing the influence of measurement system expansion and increasing measurement accuracy under dynamic temperature conditions. The DIL 803 is designed for measurements under vacuum or inert gas while the DIL 803L is designed for measurements under air, making the DIL 803L ideally suited to measuring ceramic materials

Details

DIL 802 True Differential Dilatometer

For highest measurement accuracy, DIL 802 and DIL 802L provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen, the True Differential design negates the influence of measurement system expansion on the sample measurement. This measurement design is of particular benefit for dynamic temperature programs such as those employed in Rate-Controlled-Sintering (RCS) and for measurements at lower temperatures. The DIL 802 is designed for measurements under vacuum or inert gas while the DIL 802L is designed for measurements under air.

Details

DIL 801 Single Sample Dilatometer

Suitable for a wide range of routine dilatometric tests, the DIL 801 and DIL 801L are horizontally configured single-sample dilatometers. The DIL 801 is designed for measurements under vacuum or inert gas while the DIL 801L is designed for measurements in air, making the DIL 801L ideally suited to measuring ceramic materials which are often processed in air.

Without a doubt DIL 801 and DIL 801L represent today the dilatometers with the best price / performance ratio on the market

Details

FOX 600 GHP

FOX 600 GHP is especially well-suited for thermal conductivity measurements at high temperatures, exhibiting unrivaled temperature and dimensional stability. Each of its components include state-of-art technology representing the best available today in advanced materials and electronics.

In a Guarded Hot Plate system a temperature difference (ΔT) is established across a sample of known thickness (L). The thermal conductivity is calculated from the temperature difference across the known thickness and the steady state power (W) per area (A) required to maintain the temperature difference. The Guarded Hot Plate uses a direct measurement of the electrical power supplied to the hot plate rather than heat flow meter signals from a Heat Flux Transducer.

Details

Fox 801

The FOX 801 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity according to ASTM C518 and ISO 8301. Capable to operate both in standalone or PC-controlled configurations, FOX 801 Heat Flow Meter provides rapid and accurate results. The instrument features proprietary thin film heat flux transducers, digital thickness measurements and responsive temperature control. A versatile instrument, it is especially well-suited to measuring slices of cellular plastics.

Details

FOX 600

The FOX 600 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity according to ASTM C518 and ISO 8301. Capable to operate both in standalone or PC-controlled configurations, FOX 600 Heat Flow Meter provides rapid and accurate results. The instrument features proprietary thin film heat flux transducers, digital thickness measurements and responsive temperature control. A versatile instrument, it is especially well-suited to measuring slices of cellular plastics.

Details

Fox 314

The FOX 314 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity according to ASTM C518 and ISO 8301. Operating in standalone or PC-controlled configurations, the FOX Heat Flow Meter provides rapid, accurate results. The instrument features proprietary thin film heat flux transducers, digital thickness measurements and responsive temperature control. The FOX 314 is a versatile instrument and is especially well-suited to measuring slices of cellular plastics.

Details

FOX 200

The FOX 200 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity according to ASTM C518 and ISO 8301. Operating in standalone or PC-controlled configurations, the FOX Heat Flow Meter provides rapid, accurate results. The instrument features proprietary thin film heat flux transducers, digital thickness measurements and responsive temperature control. The FOX 200 is a versatile instrument and is especially well-suited to measuring slices of cellular plastics.

Details

Fox 50

The FOX 50 Heat Flow Meter is an accurate, easy-to-use instrument for measuring thermal conductivity and provides rapid results in a compact footprint. The instrument is configured with the identical high performance features and proprietary technologies of the larger FOX systems including thin film heat flux transducers, digital thickness measurements, responsive temperature control, plus an integrated contact-resistance correction.

Details

DTC 300

DTC 300 is a guarded heat flow meter measuring the thermal conductivity over a wide range of temperatures accordingly to the ASTM E1530 Standard.

It employs one calorimeter module, located in the bottom stack, for the measurement of thermal conductivity, and a side guard furnace to prevent edge heat loss. The contact resistance is minimized by applying a pneumatic load to the test stack, and by using a thermally conductive interface compound.

Details

AHT – Automated Hardness Tester

The AHT Automated Hardness Tester streamlines the measurement of Shore A hardness for cured rubber materials. This fully programmable, automated system measures the hardness of cured rubber materials according to all international standards for Shore A hardness. Each measurement involves the determination of a user-defined number of single point Shore A values. The individual readings, mean and median of this set are reported for each sample.

Details

MV one

The MV one Mooney Viscometer incorporates the latest measurement technology for the traditional Mooney viscosity, Mooney scorch, and stress relaxation measurement in the rubber industry. The MV one is a fully featured instrument configured for standard viscosity, scorch and stress relaxation (linear, logarithmic, ISO, Mooney Stress-relaxation Rate) testing of rubber compounds under isothermal test conditions at constant speed of 2 rpm. An optional continuously variable motor mode allows tests over a speed range of 0.1 to 10 rpm. The MV one Mooney Viscometer is equipped with low mass rotors that meet all relevant ASTM, ISO, and DIN standards. All TA Instruments rubber testing instruments are constructed on ultra-rigid test frames and include direct drive motors, precision temperature control and the powerful and intuitive Scarabaeus Control and Analysis Software.

Details